Malfunction
|
Its reasons
|
Your help
|
A.Slishkom low level of hydraulic oil in a broad tank |
1. Air closed in hydraulic system, left 2. Not tight hydraulic system |
Add hydraulic oil to a mark MAX. Tighten connecting knots of hoses; put new linings. Dismantle the hydraulic pump and the steering mechanism and загерметизируйте. Inspect on tightness if it is necessary, replace the pump |
V.Tjazhelyj a steering course
|
1. Too low pressure of giving of a liquid сервонасосом 2. The steering mechanism is faulty
|
Check up pressure. If it is necessary, replace the valve of an elevated pressure or all pump Replace |
S.Shorohi in a steering |
1. Too low level of hydraulic oil. A liquid принизана air vials 2. Screw connection on the party всасывания негерметично 3. It is weakened клиновой a belt |
Remove air, add hydraulic oil
Replace linings, pour hydraulic oil Tighten
|